Eurovac Products
EIII – Double 10HP to 75HP Centrifugal Pump Central Industrial Vacuum Systems
The EIII Central Industrial Vacuum System offers high vacuum performance for up to 30+ technicians operating at the same time. The system is typically connected with galvanized tubing to conveniently located wall or hanging drops with a longest run of no more than 250’.
Application:
- 6 to 50 Tech Housekeeping Vacuum System
- 6 to 50 Tech Grinder Vacuum System
- 10 to 75 Tech Orbital Sander Vacuum System
Part Numbers:
- SYS-102-6530FS2B: Double 10HP System
- SYS-152-6038FS4B: Double 15HP System
- SYS-202-6038FS4B: Double 20HP System
- SYS-252-6042FS6B: Double 25HP System
- SYS-302-6048FS6B: Double 30HP System
- SYS-402-6054FS9B: Double 40HP System
- SYS-502-6566FS9B: Double 50HP System
- SYS-602-6566FS9B: Double 60HP System
- SYS-752-7572FS9B: Double 75HP System
Equipment Specs:
- Construction: Fully welded steel construction
- Finish: White powder coated painted finish
- Blower: QTY 2 – Centrifugal Multi-Stage Turbine Blower (energy efficient and rated for 20,000 hours of continuous operation)
- Filtration: 24” to 72” Cyclonic filter separator, after polyester cartridge filters (99.93% at 3 microns or larger) and final automatic pulse jet cleaning
- Canister: 30 to 55 Gallon
- Electrical: 208-240, 460 and 575 volts. 3 phase, 60 hertz Premium Efficiency TEFC Motor
- Blower Relief: Manual ball valve for ensuring blower does not go into “surge”
- Inlet: 4″OD to 14”OD
Control Panel Specs:
- NEMA 4 Enclosure (Indoor/Outdoor)
- Start/Stop
- Overload Protection
- Run Light
- 120v Step Down Transformer (ie: Control remote on/off switches)
- 24VDC Sequential On Demand Auto Pulse Jet. Includes Proportional Type “On Line” Cleaning, “Off Line” Cleaning
- Filter Differential Pressure (dp) Display
- Dirty Filter Fault Shutdown/Light (c/w external reset)
- General Pulse Jet Fault Light
System Performance:
- Vacuum – 6”Hg (81.6″WC) to 8”Hg (108.8”WC)
- Flow – 600 CFM to 3800 CFM
Includes:
- Silencer, 4 Anti Vibration Pads & Wedge Anchors
- Tube, Bends & Fittings Between Blowers & Separator
- Air Filter Regulator (For Pulse Jet Cleaning)
Not Included:
- Electrical Disconnect
Optional Additions:
- Controls: For double turbine systems, a lead/lag control system should be considered as it allows one turbine to start operation and the other to kick in when additional demand is required.
- Check Valves: QTY 2 – Check valves which allow each turbine to be isolated where by only vacuum is produced if that specific turbine is operating
- 600CFM Max HEPA Filtration (HEP-R18-1B0600RP)
- 900CFM Max HEPA Filtration (HEP-R24-1B0900RP)
- 1600CFM Max HEPA Filtration (HEP-R24-2B1600RP)
- 2400CFM Max HEPA Filtration (HEP-R24-3B2400RP)
- 3000CFM Max HEPA Filtration (HEP-R24-4B3000RP)
- 3800CFM Max HEPA Filtration (HEP-R30-4B3800RP)
- See Separator Options for Explosion Relief, Rotary Air Locks and more